Page 2
© 2000 Saftronics, Inc.
S
TART-UP GUIDE
GP5 / FP5
www.saftronics.com
Start-Up Procedure for the GP5/FP5
The following procedure is to assist in the start-up of the GP5/FP5 inverter, by providing a step by step
guide to installation, programming and basic operation of the GP5/FP5 inverter. The procedure is
based on several common configurations used in the industry. For more detailed configurations and
applications refer to the GP5/FP5 instruction manual (Part # 027-2005F) available at www.saftronics.com.
Installation
1. Verify that the input voltage of the supply, motor and the drive model number are all marked with the
same voltage. Caution: If improper voltage is applied to the inverter, severe damage will result.
2. Mount the inverter on a vertical surface with adequate space for proper air circulation (minimum 1.18
inches on each side and 4.72 inches above and below; (Instruction Manual Page 17).
3. Remove the front cover, connect conduit to the bottom plate, and connect power and ground wires to the
correct terminals.
Caution: Connect correct input voltage to terminal L1, L2, and L3.
Connect motor to terminals T1, T2 and T3 only or severe damage will result.
4. Replace the cover and apply voltage to the inverter. The keypad will display “Frequency Ref.
U- 01=0.00Hz”; Drive, SEQ, REF & Stop LED’s should be illuminated on the keypad. Pressing the
Local/Remote key will turn off the SEQ and REF LED’s and put the inverter into local mode (keypad
control). By pressing the RUN key and holding key until U-01= 6Hz is displayed, and then pressing
the ENTER key, will enable you to check the rotation of the motor. If the rotation is incorrect remove
power from the inverter, wait for the Charge LED to go out and then swap motor leads T1 and T2 and
then repeat step 4 to verify the rotation is correct on the application.
5. Keypad - To access any parameter, press the DSPL key until “parameter” is displayed on the LCD
readout. Use the and keys until the desired parameter is displayed then press ENTER. To change
the value in the parameter simply use the and keys and press ENTER to accept that changed
value.The keypad will then display END, to signify that the inverter has accepted the changes. For
additional programming instructions on the keypad see the GP5/FP5 Instruction Manual, part # 027-
2005F available at www.saftronics.com.